Pentair mastertemp display not working - Pentair Pool Quick Link for Parts/Equipment: https://amzn.to/3q6MXmf Ask your Questions or search from our database of answers: https://askthepoolguy.com/que...

 
Apr 23, 2017. #1. Howdy,I have a new Mastertemp 400 unit that I installed as a replacement for the old Sta-Rite Max-E-Therm 333.The unit fires up but does not heat the water.The following happens:- I push SPA button (Temperature is set to 104F), blower activates and 30s later heater fires with a wooopf. Exhaust gets nice and hot so unit is .... Which idgod is real

May 6, 2022 · Everything in my Pentair Mastertemp Heater is working properly except the LCD screen that displays the temp. I can see that the backlight is coming on but there is no display of numbers. All buttons on pad work as normal and from reading other threads I realize the LCD screen is on the control board. Mar 4, 2022 · Anybody would feel annoyed and panicked. But calm down as we have brought you the solutions for common problems that you face in Pentair MasterTemp 400. Problems like Off and On issues with your pool heater, water flow not working efficiently, the position of a heater, Temperature display, etc. These problems can be solved with just minor steps. Apr 5, 2021 · Apr 5, 2021. #8. JamesW said: Put the system in Service Mode and then press the Filter button to start the pump. Make sure that the light above the Filter button is on. Once the pump is on, press the heater button to see if the heater will come on. The heater does come on when I do it in service mode. The Pentair MasterTemp common problems include- ignition failure, temperature problems, heater keeps exit away, display not working and the heater not turning on. Besides, the heater turning on automatically, the sweetheart won’t stay lit, the blower none working, low irrigate currents, bugs codes, a faulty control panel, dirty filter, noise, freeze damage, and heat exchangerIt’s designed to be user-friendly with its rotating digital display that provides easy operation and monitoring. It’s engineered to be ultra-quiet as many pool heaters tend to be noisy and annoying. Thankfully, the …Pentair Mastertemp 250 Display Not Working. Your Pentair Mastertemp display not working is a major issue because you won’t be able to put any command on it when the display isn’t working. The problem mainly occurs due to a lack of power supply. A blown fuse or a defective control board is also highly responsible. Solution:E01 126 Error Burner Troubleshooting Heat Exchanger Troubleshooting How does a Pentair Mastertemp Swimming Pool Heater work? A Pentair Mastertemp heater is actually a very simple appliance that becomes more complicated due to all of the interlock protection.Everything in my Pentair Mastertemp Heater is working properly except the LCD screen that displays the temp. I can see that the backlight is coming on but there is no display of numbers. All buttons on pad work as normal and from reading other threads I realize the LCD screen is on the control board.CajunGuy. I went to turn on my pool heater today (hadn't turned it on in about 2-3 months) and noticed the temperature up/increase button doesn't work. I can turn down the temp setting, but the up button doesn't work to increase the setting. Everything else seems fine, it still fires up and heats up, it's just that one button isn't working.The common reasons why your Pentair MasterTemp 400 keeps shutting off are incorrectly set temperature control, incorrect wiring, low gas pressure, and a wet or damaged high-limit switch. Besides shorted or defective AGS, faulty ignition control module, clogged pool filter, faulty temperature sensor, and bad control board are also responsible …Apr 8, 2012 · Pentair MasterTemp 400 K heater Pool filter clean, strainers clean, good water flow to pool and spa. Heater will not start. spa light is on. service system & service heater lights are off heater set p … Used this to replace a 10 yr old Pentair Mastertemp 400 control board that was failing. Solved the issue, easy to install. Information was not clear that it also included the keypad. Could have used more instructions for older systems especially when the Pentair control center is turning the heater on/off.It's an easy fix, just 2 plugs for the board, takes longer to the top off then replace the board. alopgeek • 5 yr. ago. That jives with what I’m seeing. Only when it rains. I’ll see if I can cover it up with a tarp or something. Membrane pad most likely. Replace the cover over it if it's gone/missing as well.It depends on what the issue you are facing is. But most issues are fixable. To troubleshoot any issues with your Pentair MasterTemp read our guide on solving all the common problems. What does Flo mean by a pool heater? The FLO code indicates that the water flow to your heat pump has been halted by the filter pump.My pentair mastertemp seems to be working except temperature reading on the heater keeps going up when on, to 300 degrees or higher. Heater does not turn off, but reading keeps going up, up, ... The display screen on my tempmaster 400 seems to …Apr 20, 2022 · Apr 19, 2022. #1. I have a Mastertemp 400 pool and spa heater. It does 1 of 2 things currently: 1) Reads in the inlet temperature in the 90s, water is likely in the 70s. Heater will kick on and heat for about a minute before the temperature rises to 126 rapidly and kicks off the heater. 2) When turned on the water temperature shows above 104 so ... It's a fairly powerful heater and when working correctly, it'll quickly get the spa or pool to a nice temp. In recent months it's been doing something odd. The heater will kick in as expected right after the switch is flipped but after about 45 seconds or so, the "Service System" light goes on and the burner shuts off (but not the blower).Everything in my Pentair Mastertemp Heater is working properly except the LCD screen that displays the temp. I can see that the backlight is coming on but there is no display of numbers. All buttons on pad work as normal and from reading other threads I realize the LCD screen is on the control board.The regular mastertemp puts about 336,000 btu in the water every hour. The 400 hd puts about 328,000 btu in the water every hour. 35,000 gallons is 291,900 lbs, which means that you should get about 1.15 degrees per hour from the regular mastertemp or 1.12 degrees per hour from the hd model. You also have to account for heat loss, …The Pentair MasterTemp common problems include- sparking failure, temperature issue, electric keeps shutting off, display not working and the heater not …When your Pentair Mastertemp 400 refuses to turn on, check your heater’s Membrane Pad and see whether the pad is displaying the digital temp or not. If not, be sure the faulty Membrane switch is the culprit. Thus replace the malfunctioning or stuck Membrane Pad, Switch, and switch’s damaged or bad wiring. 8. Tripping Safety SwitchesI got a pentair mastertemp propane heater installed last week. Its 400k btu model number 460737. Its seems to be working fine. Its connected to the main aquarite panel. When i keep it in pool mode on my aquarite control panel, turn on heater from the aquarite. The heater turns on , but the indicator on the display panel on heater shows 'spa'.View and Download Pentair MASTERTEMP 200HD installation and user manual online. POOL AND SPA HEATER (FOR OUTDOOR USE ONLY). MASTERTEMP 200HD heater pdf manual download. Also for: Mastertemp 300hd, Mastertemp 400hd, Mastertemp 400, Mastertemp 200, Mastertemp 300. ... LCD Display: During normal heater operation the …The High-efficiency, High-tech Heater for Pools Up to 15,000 Gallons. The MasterTemp 125 Heater provides energy-savings and advanced operating features that were only available from much larger heaters. With its revolutionary pre-mixed gas combustion technology, the MasterTemp 125 Heater offers 82% thermal efficiency, the highest in its class.Cut a 3-inch piece of 14 gauge wire and strip both ends. Remove the two wire leads to the sensor you believe is at fault. Connect the two leads together with the wire jumper. Attempt to run the heater with the jumper installed between the two wire leads.Pentair MasterTemp Low NOx Pool Heater - Electronic Ignition - Natural Gas - 250000 BTU - EC-462026. 5.0 (7 REVIEWS) $3,279.00. Login to View Member's Only Pricing or click here to register. Quantity. As low as $151.30/mo*. Free Shipping. Parts Available. Jul 10, 2022 · My Spa heater is not working. It shows enabled but does not fire up and there’s nothing on the display. Contractor's Assistant: Who manufactured the spa? It is a pentair mastertemp. Contractor's Assistant: Do you plan on doing the work yourself? Don’t know, would to know what’s wrong before I schedule something. Hey guys I have pentair mastertemp 250 that I have been keeping running for 13 years and I can tell you that I have been through three button membrane pads three hot surface ignitors replaced the control board once replaced the ICM once and replaced the entire wiring harness once, replaced the Air flow switch (that was before I knew you could simply blow into it to get it to open again).When your Pentair Mastertemp 400 refuses to turn on, check your heater’s Membrane Pad and see whether the pad is displaying the digital temp or not. If not, be sure the faulty Membrane switch is the culprit. Thus replace the malfunctioning or stuck Membrane Pad, Switch, and switch’s damaged or bad wiring. 8. Tripping Safety SwitchesA common problem with the Pentair pool heater your that of displays doesn’t work. This issue often occurs when there is a problem equal an ad board or which …The Pentair Home app accepts a wide range of Pentair Connected water devices that can be used throughout a home to help your customers move, improve and enjoy their water. However, at this time, Pentair Home and Pentair Pro are not integrated with other smart home devices, or connected via voice with at home assistants like Alexa or Google Home.Chlorine. Liquid Chlorine. Jun 21, 2022. #1. Having trouble getting my EasyTouch to control the MasterTemp 400 (pool use). MT works fine when I manually control it on the MT panel. ET doesn’t seem to turn MT on or off when I turn on or off filter pump or on or off heat mode on ET, or adjust ET thermostat above/below current temp.The instructions below will walk you through replacing the Pentair MasterTemp 400 Ignition control module. Step 1: Take off the left side panel of the heater. Step 2: Disconnect the system from the Max-E-Therm heater. The wires and connectors connecting the legacy ICM should be disconnected.Make sure the pump is on and that the cords are plugged in securely. ER 2: This code means there’s a problem with the heater’s flow switch. Check to make sure that the flow switch is in the correct position and that there is no sand or other debris blocking it. ER 3: This code means that the heater has overheated.May 2, 2022 · Step 1: To get to the thermistor, remove the back panel. Use a screwdriver to take off the three screws on the panel. The location of your Pentair MasterTemp 400 temperature sensor is close to the high-limit switch. Step 2: Remove all of the thermistor’s electrical connections. When you need an alternative to shopping for used canopies for sale, a custom tent canopy is an option that lets you display a canopy with your company message. Custom-made canopies are also an option when you’re working with a space that’s...Heat Exchanger Troubleshooting How does a Pentair Mastertemp Swimming Pool Heater work? A Pentair Mastertemp heater is actually a very simple appliance that becomes more complicated due to all of the …The heater turns on, the display temp matches the pool temp. I have no - Answered by a verified Pool and Spa Expert. ... I have a Pentair Mastertemp 125. Not quite four years old with an Intermatic Multi Wave control system Desired set temperature on Intermatic hand held remote is 104 deg Current temperature on Intermat ... Tory …Above the fireman switch is a 1 1/4 amp fuse. Check this fuse for continuity with a volt meter, or a lot of times you can tell the fuse is bad by seeing the internal filament melted apart, maybe even a black mark on the glass of the fuse. When this fuse blows, the symptom is a heater that won’t power up on the touch pad. Edit.Hi Randy,Finally reached max level of frustration with the Mastertemp 250 HD Heater and Installed a new Mastertemp 250 HD Cupro-Nickel ASME version. Purchased from Pool Supply Unlimited however they w …Pentair Intellichlor IC-60. Apr 7, 2020. #2. The MasterTemp panel and the IntelliTouch panel operate independently. They do not synch up. They each have their own independent temperature sensors and displays. The temperature on the MasterTemp should be set to max temperature of 104 and the IntelliTouch will control the heater.Check that the breaker supplying power to the heater is not tripped. Turn the breaker off fully then back on. With the power supply breaker off. Remove the side panel just below the heater control panel . There will be a metal box. Loosen the screw on top right side of the box. The door will drop open.40,426. Sep 14, 2020. #2. freebsdrules said: It cycles through this a few times and then turns off and the service heater light comes on. I checked underneath on the board and no control board lights come on aside from E11. Checked and the red LED on the Fenwal ignition control module is not on or blinking.The common reasons why your Pentair MasterTemp 400 keeps shutting off are incorrectly set temperature control, incorrect wiring, low gas pressure, and a wet or damaged high-limit switch. Besides shorted or defective AGS, faulty ignition control module, clogged pool filter, faulty temperature sensor, and bad control board are also responsible …Apr 1, 2020 · 2. Press ^TEMP or down TEMP for 5 seconds. The display will flash once and change modes (°C to °F or vice versa). 3. Turn the Operating Control ON. When either the ^TEMP or down TEMP buttons are depressed, the digital display will indicate the temperature setting. After five seconds, the display will return to the actual pool/spa temperature. Pentair MasterTemp 250 Display Not Working | Trouble Free Pool | Pentair MasterTemp 250 Display Not Working Sound Sunrise Everyone, Were …In this video I will show you what steps I went through to troubleshoot the no heating issue with my Pentair MasterTemp 250 pool heater.#pentair #poolheater ...Automatic Gas Shutoff sensor “AGS” link to order through Amazon below:https://www.amazon.com/gp/product/B004VTGFYQ/ref=as_li_qf_asin_il_tl?ie=UTF8&tag=mopar...Oct 4, 2020 · I do have an ET. Based on these suggestions I may try to calibrate the water temp sensor from the ET and see if it will save. The main issue is it is not saving from the app. Or it’s faulty. This is what I understood. Please correct me if wrong. The ET sends the set point to the heater which kicks it on initially. May 21, 2022 · Make sure the sensor is properly mounted. 2. Defective Thermal Regulator. If the sensor is quite in good condition and hooked to the control board easily, there is the suspect of a defective thermal regulator of the pool heater. Now, if the display is still showing the wrong temperature, you have to check out the thermal regulator this time. The common reasons why your Pentair MasterTemp 400 keeps shutting off are incorrectly set temperature control, incorrect wiring, low gas pressure, and a wet or damaged high-limit switch. Besides shorted or defective AGS, faulty ignition control module, clogged pool filter, faulty temperature sensor, and bad control board are also responsible …5. Low Water Flow. An obstruction in your pool system can prevent your heater from turning on due to limited water flow. Solution: Ensure that your pool filter is clean. Empty the baskets. Make sure the pump is sending enough water through the system. 6. Dirty Heat Exchanger.I do have an ET. Based on these suggestions I may try to calibrate the water temp sensor from the ET and see if it will save. The main issue is it is not saving from the app. Or it’s faulty. This is what I understood. Please correct me if wrong. The ET sends the set point to the heater which kicks it on initially.In today’s digital age, we are constantly bombarded with an overwhelming amount of information. From work documents to personal files, it can be challenging to keep track of everything. However, there are ways to bring order to this chaos a...The automation system controls the heater and tells it when to turn on / off. The heater should be set at 104 and let the automation do the rest. The mastertemp display doesn't light up when controlled remotely. Wiring it to a 2 wire remote interrupts the circuit for it to power up. Not sure why a pool tech wouldn't replace the 2 wire remote ...Funmit###-##-#### Stack Flue Sensor Replacement for Pentair Sta-Rite MasterTemp Max-E-Therm Pool and Spa Heater Electrical System SR200 SR333 SR400 https://a.co/d/hJprf15 Ask Your Own Pool and Spa Question5.0 (1 REVIEW) $107.78. Quantity. Pool Supply Unlimited has some of the best prices when shopping for Pentair MasterTemp Membrane Pad Kit | 472610Z.My Pentair heater is not working and displaying err ps. 2months. ... HI! I have a Pentair 400 mastertemp propane spa heater. The service system light is on, and it has two red lights on, on the reverse side of the motherboard. The PS is red, and led6 is red.I do have an ET. Based on these suggestions I may try to calibrate the water temp sensor from the ET and see if it will save. The main issue is it is not saving from the app. Or it’s faulty. This is what I understood. Please correct me if wrong. The ET sends the set point to the heater which kicks it on initially.Good Morning Everyone, We opened our pool a couple of past ago with no issues. We went to turn up the heat yesterday and the display that shows the …Your Pentair pool heater demonstrate not working can be a result of a lack of power supply, an blows fuse, or a defective control board. Get their Pentair pool beheizung getting guide to solution this issuance ASAP. Pentair Pool Heater Presentation Not Working [3 Easy Fixes] In this section, we will explore the reasons behind. 6.The display will flash once and change modes (°C to °F or vice versa). 3. Turn the Operating Control ON. When either the ^TEMP or down TEMP buttons are depressed, the digital display will indicate the temperature setting. After five seconds, the display will return to the actual pool/spa temperature.Apr 5, 2021. #8. JamesW said: Put the system in Service Mode and then press the Filter button to start the pump. Make sure that the light above the Filter button is on. Once the pump is on, press the heater button to see if the heater will come on. The heater does come on when I do it in service mode.The Pentair Home app accepts a wide range of Pentair Connected water devices that can be used throughout a home to help your customers move, improve and enjoy their water. However, at this time, Pentair Home and Pentair Pro are not integrated with other smart home devices, or connected via voice with at home assistants like Alexa or Google Home. The Pentair Pool Products Control Board Kit 42002-0007S is compatible with the Pentair MasterTemp 250 gas heater. Attached please find an exploded parts diagram for the Pentair MasterTemp Heater Electrical System for reference (part #15).Hey guys I have pentair mastertemp 250 that I have been keeping running for 13 years and I can tell you that I have been through three button membrane pads three hot surface ignitors replaced the control board once replaced the ICM once and replaced the entire wiring harness once, replaced the Air flow switch (that was before I knew you …Apr 5, 2021. #8. JamesW said: Put the system in Service Mode and then press the Filter button to start the pump. Make sure that the light above the Filter button is on. Once the pump is on, press the heater button to see if the heater will come on. The heater does come on when I do it in service mode.what part of the Pentair MasterTemp 400,000BTU heater governs the shutdown of the heater if you have a momentary drop in gas pressure to the heater. We have changed the igniters, gas valve and control … read moreOur pentair master temp 250 is not working. It has a red light that indicates it needs to 'service system.' what - Answered by a verified Pool and Spa Expert ... Let me know if this changes the light. If you are comfortable opening up the heater, then we can look at the led display inside the control module, there should be a code there that …I have a Jandy RS pool controller and a Pentair MasterTemp 400 NG heater. All is working but not full potential. The Jandy control panel has an option, 1 button for pool heat, 1 button for spa heat. Both are simply on/off. I have to manually push the specific buttons on the Pentair unit to switch from spa to pool heat.Turn on the heat on the EasyTouch so the heater turn on and the front panel lights up. Press SPA ON. Then use the TEMP UP red arrow to raise the temperature to 104. Ignore the 319 in the picture below. Normally it displays the water temperature or the set temperature when you are adjusting it.A code is E06 call on my Pentair heater and a changed the sensor but heater still not working. And now I get 128 and heater goes blank what should I do now? ... My pentair 400 mastertemp is not heating the display is. my pentair 400 mastertemp is not heating the display is showing a r+8 128 code ...The Pentair Compool, and LX80 Control Systems use a different TS5L sensor . Press the Program key. Press the Spa Heat Source key. Enter correct pool temperature (using the up and down arrow keys) and press Spa Heat Source key. At this point, you can just hit the Program key and exit calibration. Enter correct solar …An IntelliTouch control systematischer takes the work out of scheduling and operating ... Android™ is a mark of Google, Inc. Brand New Pentair masterTemp 400 heater. After recent big Texas freeze, power has trim off for 3 days. Can’t recall if I had power to Heater once power came back, when don’t believe so. Replaced Basic Manifold to getting pool …Inspect & clean pump impeller. Adjust Plumbing valves. Repair suction air leaks. Make sure external water bypass around heat pump is closed. With water flowing, check resistance of water pressure switch, if open, replace switch. Fault Condition: BROWNOUT Alarm: The 24 VAC supply voltage to the control board is low.Pool control at the touch of a wrinkly finger. Smart phone control, voice control, smart watch control…it’s smart pool control. Wherever, whenever and however you want. Whether you’re installing a pool, or reconstructing one, Pentair has the latest technology to keep you in touch with your pool’s every function and feature. From anywhere.Very compact design for such a high performance heater allows for smaller overall equipment pads that won't intrude on your poolscape. Easy to install or retrofit in even the tightest spaces. A fully pre-mixed system with a highly efficient air and gas mixture lets MasterTemp heat up fast. No long waits before enjoying your pool or spa.3. Broken Thermal Regulator. A broken thermal regulator or thermostat is another reason why you may be getting the wrong temperature on your Pentair MasterTemp 400’s display. Solution: You can take out the thermal regulator and test its continuity. The Thermal Regulator is situated between the inlet and outlet fittings in the Inlet/Outlet ...The heater function might not be enabled for spa under the heater. Go to advanced system setting then installation setup then heaters. Make sure affiliated body is pool/spa. Your heater has no idea if it’s heating a pool, spa, bathtub or fish pond. “Spa on” and “Pool on” are just 2 different temperature settings.

A Answered on 2/7/2022 by InyoPools Product Specialist Craig C.. Hello Steve. The Pentair Pool Products Control Board Kit 42002-0007S is compatible with the Pentair MasterTemp 250 gas heater. Attached please find an exploded parts diagram for the Pentair MasterTemp Heater Electrical System for reference (part #15).. Mature big naturals

pentair mastertemp display not working

The Pentair MasterTemp common problems include- ignition failure, temperature problems, heater keeps exit away, display not working and the heater not turning on. Besides, the heater turning on automatically, the sweetheart won’t stay lit, the blower none working, low irrigate currents, bugs codes, a faulty control panel, dirty filter, noise, freeze damage, and heat exchangerNov 8, 2021 · Hey guys I have pentair mastertemp 250 that I have been keeping running for 13 years and I can tell you that I have been through three button membrane pads three hot surface ignitors replaced the control board once replaced the ICM once and replaced the entire wiring harness once, replaced the Air flow switch (that was before I knew you could simply blow into it to get it to open again). The 10 Best Pool Heaters of 2023. Raypak 014951 Digital Cupro-Nickel Propane 266,000 BTU Pool Heater. Pentair MasterTemp 125 Low NOx Pool Heater. Raypak PR266AENX51 240,000 BTU Heater …Above the fireman switch is a 1 1/4 amp fuse. Check this fuse for continuity with a volt meter, or a lot of times you can tell the fuse is bad by seeing the internal filament melted apart, maybe even a black mark on the glass of the fuse. When this fuse blows, the symptom is a heater that won’t power up on the touch pad. Edit.Pentair MasterTemp 400 Common Problems [15 Easy Fixes] 1. Ignition Failure Solution: 2. Temperature Problems i) No Heat Solution: ii) Displaying Wrong Temperature Solution: iii) Overheating Solution: 3. Heater Keeps Shutting Off Solution: 4. Display Not Working Solution: 5. Heater Won’t Turn On Solution: 6. Heater Turns On Automatically ...5.0 (1 REVIEW) $107.78. Quantity. Pool Supply Unlimited has some of the best prices when shopping for Pentair MasterTemp Membrane Pad Kit | 472610Z.Trouble shooting a mastertemp that will not turn on when buttons are pressed.PENTAIR MASTERTEMP 400 turns on. Goes through the standard boot up procedure (128/R13 appear on the LCD of heater) Then the display shows "1". The heater fires up and starts heating for about 3-4 minutes. Then it errors out with E01... and keeps the code on for a long while. I check the back of the control board in the heater and the …According to About.com, good students are self-motivated, display leadership, work hard and solve problems effectively. About.com explains that good students ask questions when they do not understand a concept.In this video I will show you what steps I went through to troubleshoot the no heating issue with my Pentair MasterTemp 250 pool heater.#pentair #poolheater ...Hello Steve. The Pentair Pool Products Control Board Kit 42002-0007S is compatible with the Pentair MasterTemp 250 gas heater. Attached please find an exploded parts diagram for the Pentair MasterTemp Heater Electrical System for reference (part #15). Pentair MasterTemp Heater Electrical System Reply ? The Pentair MasterTemp common problems include- ignition failure, temperature problems, heater keeps exit away, display not working and the heater not turning on. Besides, the heater turning on automatically, the sweetheart won’t stay lit, the blower none working, low irrigate currents, bugs codes, a faulty control panel, dirty filter, noise, freeze damage, and heat exchanger#1 Hi Y'all, New to the pool equipment repair world, so I've watched a ton a videos, and am trying my best to repair my Mastertemp200 that won't heat. I've already watched 2 dozen videos, and made some progress, but now I'm stuck about what to replace next.The High-efficiency, High-tech Heater for Pools Up to 15,000 Gallons. The MasterTemp 125 Heater provides energy-savings and advanced operating features that were only available from much larger heaters. With its revolutionary pre-mixed gas combustion technology, the MasterTemp 125 Heater offers 82% thermal efficiency, the highest in its class. Oct 25, 2021 · The blower starts first, which should close the air flow switch. Once the Air Flow Switch closes, the TH terminal get 24 VAC to activate the HSI (Hot Surface Ignitor). After 20 seconds, the VAL (Gas Valve) terminal gets 24 VAC to power the gas valve. The ignition should happen within about one or two seconds. Mar 4, 2022 · Anybody would feel annoyed and panicked. But calm down as we have brought you the solutions for common problems that you face in Pentair MasterTemp 400. Problems like Off and On issues with your pool heater, water flow not working efficiently, the position of a heater, Temperature display, etc. These problems can be solved with just minor steps. Turn on the heat on the EasyTouch so the heater turn on and the front panel lights up. Press SPA ON. Then use the TEMP UP red arrow to raise the temperature to 104. Ignore the 319 in the picture below. Normally it displays the water temperature or the set temperature when you are adjusting it.Good Morning Everyone, We opened our pool a couple of past ago with no issues. We went to turn up the heat yesterday and the display that shows the temperature is no displaying anything. I am able to pressure to "pool on" button and this green lamp will show up, however, nothing appeared on the...It depends on what the issue you are facing is. But most issues are fixable. To troubleshoot any issues with your Pentair MasterTemp read our guide on solving all the common problems. What does Flo mean by a pool heater? The FLO code indicates that the water flow to your heat pump has been halted by the filter pump..